How to assess data quality in the OptoScale web portal?
In some cases, data quality can be affected by data capture, the bioscope’s position or the conditions in the pen. This guide explains how to assess data quality and what you can do if the data deviates or seems uncertain.
The OptoScale web portal shows data and measurements based on images of the fish taken by the bioscope in the pen. For the measurements to be as representative as possible, good and stable data capture is essential.
Best practice is to have one person responsible per site who checks the web portal daily. We recommend checking the operational status and monitoring data capture and data quality for each module.
In short
- Ensure good data capture first. More registrations provide a better basis for the measurements.
- Look at the trend over time, not at individual measurements.
- Deviating measurements do not necessarily mean poor data quality. Check whether there is a natural explanation.
1. Ensure good data capture
An important prerequisite for good data quality is that the Bioscope captures images of a sufficient number of fish. The more registrations over time, the better the basis for accurate estimates and precise data.
Position the bioscope so that the fish naturally swim past the camera. See the user manual for more information on installation and deployment.
What counts as good data capture depends on, among other things:
- The number of fish in the pen
- Whether it is a hatchery or a sea site
|
At sea sites, there is normally a good data basis for the various modules when the number of approved weight measurements is over 5 000 per day. |
2. What to do if data capture is low
If the number of measurements is low over time, we recommend the following steps:
- Check the bioscope status and data capture. Check the operational dashboard, images, live video and image classes to find the cause.
- Compare with other bioscopes at the site. Do one or more pens have lower data capture? Compare position and depth with pens that have better data capture.
- Check where the fish are in the pen. Use the feeding camera to see where the fish are, compared with the Bioscope’s position.
- Adjust the bioscope. If your checks indicate that the position is affecting data capture, the bioscope should be adjusted.
Common causes of low data capture
- Obstructions in front of the camera
- The fish swim too far from or too close to the Bioscope
- Fouling on the lenses
- The bioscope is hanging at an angle
- The bioscope is at a depth or in a position with few fish
3. How to assess data quality
When data capture is good, we have a solid basis for assessing data quality. The following signals in the data may indicate that the measurements should be examined more closely:
|
Signal |
What it may mean |
|
Fluctuating weight development or high CV |
Fish of different sizes are being measured. This may be due to genuinely large variation within the fish group, but it may also indicate that a non-representative group of fish is being measured (loser fish). A high CV can increase the uncertainty of the measurements, and large variation in the data can affect estimated growth. |
|
One pen stands out |
If one or more pens clearly stand out from the rest, for example in weight development or other parameters, this should be examined more closely. If the difference cannot be explained by known factors affecting the fish group, it may indicate that the Bioscope is not measuring on a representative basis. |
|
Remember: Deviating data does not necessarily mean that data quality is poor. There may be real changes in the fish group. |
4. What to do if data quality is uncertain
If the measurements seem abnormal or do not match expectations, we recommend the following approach:
- Check data capture. Make sure data capture is good and stable. If it is low, follow the steps in section 2.
- Consider whether the situation is temporary. The change may be caused by conditions that are expected to pass. For example, recent activity or operations at the site, reduced visibility/algal blooms, temperature changes, changes in feeding regime or appetite can temporarily affect fish behavior. Look at the trend over time. Do not draw conclusions from individual measurements.
- Compare the measurements with what is actually happening in the pen. Is there a natural explanation? Disease, reduced feeding or other changes in the condition of the fish can lead to changes in the measurements. Check whether the deviation is due to real factors in the fish group or in operations.
- Adjust the bioscope if deviations are persistent or unexplained. If the measurements do not make sense over time, or deviate significantly without an obvious explanation, the bioscope’s position should be adjusted.
|
NOTE: Adjusting the bioscope at deep-farming facilities and hatcheries is more complex, as the bioscope’s starting position, suspension and net type may vary. Contact our technical support for guidance. |
|
Moving the bioscope or fish: For the best possible data quality, we recommend moving the bioscope together with the fish whenever possible. This makes it possible to continue the same data series. The site can change pen names under Settings in the web portal. |